Anti-collision warning sphere for power transmission lines
Contact Info
- Add:Room C-9, Building C, Precision达 Industrial Park, No.39 Qingfeng Avenue, Longgang Sub-district, Longgang District, Shenzhen City, Zip: 518116
- Contact: 小李
- Tel:18820479231
- Email:2512646832@qq.com
Other Products
Alternative product names: Three-cross transmission line traffic warning ball, intelligent warning aviation marker ball, external damage prevention warning ball for transmission lines, high-voltage line external damage prevention intelligent warning ball, equipotential flashing external damage prevention warning ball for transmission lines, etc.
Product model: TLKS-PLSA-II
I. Introduction
In modern society, electricity, as a key energy source supporting the operation of all industries and people's daily lives, its transmission network is like a huge network, spreading across the streets of cities, the vast fields of rural areas, and between mountains and rivers. However, with the acceleration of urbanization, various construction activities have become increasingly frequent, coupled with the gradual increase of low-altitude flying objects, transmission lines are facing unprecedented challenges. Under the lines, pedestrians' accidental approach, misoperation of high-altitude operation vehicles, especially in poor lighting conditions at night, a slight mistake may cause electric shock accidents, bringing huge impacts on people's lives and property safety. According to incomplete statistics, the annual casualties and economic losses caused by high-voltage line external damage accidents are astonishing. In the face of such a severe situation, relying on our profound technical accumulation and keen insight into market demands, our company has carefully developed the external damage prevention warning ball for transmission lines (TLKS-PLSA-II), building a solid defense line to prevent high-voltage line external damage accidents.

II. Product Overview
The external damage prevention warning ball for transmission lines (TLKS-PLSA-II) is easy to install and can be directly fixed on the conductor of the transmission line. At night, the internal red LED screen automatically lights up, warning passing pedestrians, vehicles and ships with high brightness, reducing the risk of night accidents. It is equipped with a high-sensitivity sensor that can detect foreign objects in real time. Once an object approaches to the preset distance, the system will immediately activate the linked voice warning unit, and the siren and flashing warning light will turn on at the same time, reminding tower crane operators and low-altitude flying objects to stay away from high-voltage lines with strong sound and light signals, ensuring the safety of personnel and property in all aspects.
III. Innovative Working Principle, All-round Safety Protection
The external damage prevention warning ball for transmission lines (TLKS-PLSA-II) is extremely easy to install and can be directly fixed on the conductor of the transmission line. At night, the red LED screen built in it will automatically light up and display with extremely high brightness, like a red lantern in the dark, clearly warning passing pedestrians, vehicles and ships, greatly reducing the risk of accidents caused by poor visibility. What's more outstanding is that it is equipped with a high-sensitivity sensor that can detect foreign objects such as people and vehicles in real time. Once an object approaches the preset distance, the system will immediately activate the linkage mechanism and trigger the voice warning unit. At this time, the siren will make a sharp sound, and the flashing warning light will turn on synchronously, reminding tower crane operators and low-altitude flying objects with strong sound and light signals not to approach high-voltage lines, ensuring the safety of personnel and property in all aspects.

IV. Product Functions
1. Obtain power through conductor induction power supply, with stable and reliable power supply;
2. Wide application range, suitable for voltage levels from 10kV to 500kV;
3. Adopt long-life, high-brightness light-emitting devices, with high brightness and strong penetration, flashing to warn the existence of the line;
4. Equipped with lightning protection, anti-corrosion, anti-rust, waterproof and dustproof technologies, and anti-vibration fatigue, ensuring stable operation in harsh environments;
5. With anti-electromagnetic interference capability;
6. Detection distance: 3-6 meters, adjustable at factory, alarm sound: >95DB;

V. Technical Parameters
1. Working voltage: AC10KV~500KV
2. Maximum brightness: >3000lm
3. Ambient temperature: -40℃~80℃
4. Ambient humidity: 0~100%
5. Impact current: 40Ka/60ms, 15kA/100ms
6. Light source visibility: >100m
7. Product specification: 280mm (diameter)

VI. Future Outlook
The external damage prevention warning ball for transmission lines (TLKS-PLSA-II), with advanced technology and reliable performance, has become a key equipment for the power industry to prevent power grid accidents. In complex and changeable environments, it always operates stably and reliably, providing solid protection for the safety of the power transmission network.
The product is customizable. The quoted price is a reference price when it is currently released in the market, and the actual price is subject to negotiation. If you want to know more product information, please feel free to contact Ms. Li from Teluck Technology, mobile: 18820479231, WeChat and QQ are the same
| Industry Category | Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards |
|---|---|
| Product Category | |
| Brand: | 特力康 |
| Spec: | TLKS-PLSA-II |
| Stock: | 999 |
| Manufacturer: | 深圳市特力康科技有限公司 |
| Origin: | 114403 |